They should all work the same. If they don't, I would look for the hardware application they are working in. Power supply, power / bus noise, grounding problems, etc. Grounding problems alone can cause unpredictable behaviour across different implementations. -- Sent from mobile device. Please have understanding. On 30 March 2016 10:06:21 CEST, didier derny <didier@aida.org> wrote: >I have a problem with a read with a 6502 > >I read a data on a register (from a CH376S) > >I have the following code: > > *= 2000 >readdata LDA CH376data > RTS > > >this code always get the wrong value > > *= 2001 >readdata LDA CH376data > RTS > > >now with this code I get the right value... > >I have a diffent result with a 6502 from: > >mos technology sometimes good (even addresses) / always good >rockwell always bad (even addresses) / always good >(odd >addresses) >WDC not working both cases >bulgarian clone not working both cases > >any idea ? I dont really know what to think... > > > > > > > Message was sent through the cbm-hackers mailing list Message was sent through the cbm-hackers mailing listReceived on 2016-03-30 10:00:54