Hallo Mia,


> Well, with an ATN trap you could get away with no interrupt as the timeout is iirc infinite on the computer.

When handling the command DIRECTORY, the IEEE drive receives various ATNs from the CBM. Until now I have no idea why the CBM does this but it does so I had to act on and handle them. They are not send at random so I figured out when they were sent and I adapted my software. Then I met this Belgian guy with his device that asked for a directory and my software couldn't cope with it because it expected ATNs at various places that didn't come anymore or came at the wrong place. 
That's why I decided to give it another try to hook the ATN input to an INT input. I tried that before but it never worked. This time I found out what I did wrong (forgot to reset the 8259) and things work fine. The software just sends the directory byte by byte and if a ATN is sent, the interrupt routine checks whether the software should pay attention to it or not.


With kind regards / met vriendelijke groet, Ruud Baltissen

http://www.baltissen.org




De informatie in dit e-mailbericht is vertrouwelijk en uitsluitend bestemd voor de 
geadresseerde. Wanneer u dit bericht per abuis ontvangt, verzoeken wij u contact op te 
nemen met de afzender per kerende e-mail. Verder verzoeken wij u in dat geval dit 
e-mailbericht te vernietigen en de inhoud ervan aan niemand openbaar te maken. 
Wij aanvaarden geen aansprakelijkheid voor onjuiste, onvolledige dan wel ontijdige 
overbrenging van de inhoud van een verzonden e-mailbericht, noch voor daarbij 
overgebrachte virussen.

APG Groep N.V. is gevestigd te Heerlen en is ingeschreven in het 
handelsregister van de Kamer van Koophandel Limburg onder nummer 14099617


The information contained in this e-mail is confidential and may be privileged. 
It may be read, copied and used only by the intended recipient. 
If you have received it in error, please contact the sender immediately by 
return e-mail; please delete in this case the e-mail and do not disclose its 
contents to any person. We don't accept liability for any errors, omissions, 
delays of receipt or viruses in the contents of this message which arise as a 
result of e-mail transmission.

APG Groep N.V. is registered in the trade register of the Chamber 
of Commerce Limburg, The Netherlands, registration number: 14099617
Received on 2020-05-30 00:11:06

Archive generated by hypermail 2.3.0.