On Sun, Jan 03, 2021 at 09:45:39PM +0100, groepaz_at_gmx.net wrote: > Not every detail in the design is clocked, some delays just happen because of > gate propagation delays - and when the process changes, those delays may > change as well. Yup, exactly. > The well known "grey dot" the new VICII produces are related > to exactly the same thing. But this isn't true at all. You get the grey dot if *external* timing is off! The difference isn't between VIC-II versions, the difference is between boards (and what PLA or PLA replacement is used on that). SegherReceived on 2021-01-04 18:00:39
Archive generated by hypermail 2.3.0.