Hallo Marko, > They do matter on the C128, however. Ruud's question regarding the C128 > cartridge port in 2 MHz mode is still unanswered, by the way. Could > someone verify if the cartridge port bus is available all the time in the > 2 MHz mode (minus the 5 RAM refresh cycles per raster line)? It just occured to me that, IIRC, when in 2 MHz mode the C128 goes back to 1 MHz when acessing the I/O-area. This would mean that all accesses by CPU allways are in 1 MHz :( If someone has a scope and C128 at hand, the only thing he has to do is to put the C128 in 2 MHz mode, to pull DMA to GND and measure CLK2. Groetjes, Ruud http://Ruud.C64.org - This message was sent through the cbm-hackers mailing list. To unsubscribe: echo unsubscribe | mail cbm-hackers-request@dot.tml.hut.fi.