Re: eagle routing problem

From: silverdr_at_wfmh.org.pl
Date: Thu, 28 Dec 2017 09:11:15 +0100
Message-Id: <84D2141C-2B20-4517-9FEA-49A0025E81D4@wfmh.org.pl>
> On 2017-12-28, at 08:11, Baltissen, GJPAA (Ruud) <ruud.baltissen@apg.nl> wrote:
> 
> Hallo Didier,
> 
> 
>> any idea to this routing problem ?
> 
> What are you using as 6502 socket, another 6502? If so, a check on the schematic will reveal that you are trying to connect output pins to other output pins, for example the address bus. It is possible that that is the reason the board refuses to connect those pins. 
> I solved the original error by copying the original 6502, made all pins passive and called the copy 6502DEBUG (because it was meant for my debugger tool). Connecting a output pin to a passive pin is no error. But I didn't use the resulting schematic to create a board so I'm not sure if this solves your problem.

Connecting inputs to outputs affects schematics module and should pop up as ERC points. It shouldn't affect routing though. I expect rather some DR related issue.

-- 
SD! - http://e4aws.silverdr.com/


       Message was sent through the cbm-hackers mailing list
Received on 2017-12-28 09:00:48

Archive generated by hypermail 2.2.0.