On Mon, 31 Jul 2000, Richard Atkinson wrote: > I looked at them in BASIC a few years ago but have never 'sampled' them > properly. With an REU it is possible to sample 512K of data without > interruptions at 256 byte boundaries I've looked at the combined waveforms by sampling the OSC3 register every 16 or 32 cycles (I don't remember; anyway, I wrote the sampling loop so that crossing 256-byte boundaries made no difference in the sampling frequency). At double waveform frequency, the output changes at double speed; there are no irregularities. The cycles of the waveforms were 512 bytes, unless I remember wrong. This information is for the 6581; I haven't tested the new SID. So, there's no need to have a REU to measure the waveforms. Marko - This message was sent through the cbm-hackers mailing list. To unsubscribe: echo unsubscribe | mail cbm-hackers-request@dot.tcm.hut.fi.