On 6/28/2018 8:14 AM, Jeff Laughton wrote: > > > Hi, Jim. You'll find some details about timing *differences* in Table > 7-1 of WDC's 65c02 datasheet [1], which makes a comparison with the > NMOS 6502. On the 'C02 the $6C opcode (jmp indirect) takes one cycle > longer. ADC and SBC also apparently take one cycle longer if you're in > decimal mode. I am using a Rockwell 65C02. Any info on those? I don't know that I have a 65c02s here yet. JimReceived on 2018-06-29 04:00:25
Archive generated by hypermail 2.2.0.